Product

Back

S4D500-AD03-01

Brand:
ebmpapst
Document:
Category:
Axial Fan
Description:
Type: AC Axial Fan
Air output (m³/h): 9590
Speed ​​(RPM): 1325
Min. Ambient Temperature: -40 °C
Application: Condenser Refrigeration Air Conditioner Axial Cooling Fan

Nominal data

Brand:
ebmpapst
Part No.:
S4D500-AD03-01
Fan Type:
Axial Fan
Rated Voltage(V):
400
Size(mm):
500
Max.Air Flow(m³/h):
9590
Max.Pressure(Pa):
160
Input Power(W):
820
Speed(rpm):
1325
Noise(dB):
71

Description

 ebmpapst S4D500-AD03-01 Specification Drawing:

AC Axial Fan for Refrigeration and Condenser Cooling

The S4D500-AD03-01 is particularly suitable for applications where air needs to be moved across heat-exchange surfaces.

In condenser and refrigeration equipment, airflow is an important part of the heat-transfer process. The fan moves ambient air through or across the heat exchanger, helping the system transfer heat effectively under its designed operating conditions.

With a maximum airflow of 9,590 m³/h, the S4D500-AD03-01 can be considered for medium-to-large cooling equipment where a 500 mm axial fan matches the required installation dimensions and operating point.

Typical application areas include:

  • Refrigeration equipment
  • Condensing units
  • Air-conditioning systems
  • HVAC equipment
  • Heat exchangers
  • Industrial cooling equipment
  • Ventilation systems

Actual fan suitability should be determined according to the required airflow, system resistance, installation conditions and electrical requirements.

S-Series Sickle-Blade Axial Fan Design

The S4D500-AD03-01 belongs to the ebm-papst S-series axial fan range and uses sickle-shaped blades.

The fan has five aluminium-sheet blades and a 500 mm size. The direction of airflow is designated as “V”, while the direction of rotation is counter-clockwise when viewed from the rotor.

This axial configuration is well suited to applications involving heat exchangers, condensers and other equipment where a large volume of air needs to be moved through a relatively compact fan installation.

Designed for Equipment Integration

The S4D500-AD03-01 is equipped with a guard grille for a short nozzle, allowing the fan to be integrated into appropriately designed cooling and ventilation equipment.

The fan uses ball bearings and supports continuous S1 operation. Electrical connection is made through the terminal box.

Its mounting position can be shaft-horizontal or with the rotor on the bottom. Installation conditions should always be checked against the requirements of the equipment before mounting the fan.

IP54 Protection and Motor Construction

The S4D500-AD03-01 has an IP54 protection rating and Class F insulation.

The fan construction includes:

  • Aluminium-sheet blades
  • Cast-aluminium rotor surface
  • PP plastic terminal box
  • Steel guard grille with black plastic coating
  • Ball-bearing motor
  • Thermal overload protector
  • Rotor-side condensate discharge holes

These design characteristics make the fan suitable for integration into industrial cooling, refrigeration and HVAC equipment when the operating environment is within the specified product limits.

Selecting the S4D500-AD03-01

Fan selection should not be based on maximum airflow alone.

For a new refrigeration, condenser or HVAC project, both the required airflow and the system resistance should be considered. Heat exchangers, coils, protective grilles and equipment structures create resistance to airflow and influence the actual operating point of the fan.

Before selecting the S4D500-AD03-01, check:

  • Required airflow
  • Required static pressure
  • Rated voltage
  • Available installation space
  • Fan diameter
  • Mounting arrangement
  • Operating temperature
  • Electrical connection
  • Application environment

The S4D500-AD03-01 has a maximum airflow of 9,590 m³/h and maximum pressure of 160 Pa. The actual operating point should be checked against the requirements of the complete system.

S4D500-AD03-01 for Replacement Applications

When replacing an existing fan, use the complete part number S4D500-AD03-01 rather than selecting a replacement based only on the S4D500 series designation.

Different S4D500 versions can have different electrical and performance characteristics. A similar fan diameter does not automatically mean that two models are interchangeable.

For replacement projects, compare:

  • Complete model number
  • Rated voltage
  • Fan diameter
  • Airflow and pressure requirements
  • Input power
  • Rotational speed
  • Mounting dimensions
  • Direction of airflow
  • Electrical connection

If the original fan nameplate is still available, a clear photo of the nameplate can help confirm the exact model before ordering.

S4D500-AD03-01 FAQ

Q1. What type of fan is the S4D500-AD03-01?

A1. The ebm-papst S4D500-AD03-01 is a 500 mm AC axial fan. It belongs to the S-series and uses sickle-shaped axial fan blades.

Q2. What is the rated voltage of the S4D500-AD03-01?

A2. The rated voltage of the S4D500-AD03-01 is 400 V. The electrical supply and connection requirements should be checked before installation or replacement.

Q3. What is the maximum airflow of the S4D500-AD03-01?

A3. The maximum airflow is 9,590 m³/h. Actual airflow after installation depends on the operating point and resistance created by components such as heat exchangers, coils and grilles.

Q4. What is the maximum pressure of the S4D500-AD03-01?

A4. The maximum pressure is 160 Pa. Both airflow and pressure requirements should be considered when determining whether this fan is suitable for a specific cooling or ventilation system.

Q5. What is the speed of the S4D500-AD03-01?

A5. The listed speed is 1,325 rpm, with an input power of 820 W.

Q6. What applications can use the S4D500-AD03-01?

A6. The S4D500-AD03-01 can be considered for refrigeration equipment, condensers, air-conditioning systems, HVAC equipment, heat exchangers and industrial cooling applications where its electrical, dimensional and performance characteristics meet the system requirements.

Q7. Does the S4D500-AD03-01 have IP protection?

A7. Yes. The S4D500-AD03-01 has an IP54 protection rating and Class F insulation. Installation conditions and environmental requirements should still be checked for the specific application.

Q8. Can another S4D500 fan replace the S4D500-AD03-01?

A8. Another S4D500 model should not automatically be considered a direct replacement. Different versions may have different airflow, pressure, power, speed, electrical and mechanical characteristics. Always compare the complete part number and technical specifications before substitution.

Q9. What should I check before replacing an S4D500-AD03-01?

A9. Check the complete model number, rated voltage, fan size, airflow, pressure, power, speed, mounting arrangement and electrical connection. For existing equipment, the fan nameplate and installation dimensions are particularly useful for confirming the correct replacement.

Q10. What information should I provide when requesting the S4D500-AD03-01?

A10. Provide the complete model number S4D500-AD03-01, required quantity and application information. For replacement projects, providing a clear photo of the existing fan nameplate can also help confirm the model.

Request S4D500-AD03-01 Product Information

Looking for the ebm-papst S4D500-AD03-01 for a refrigeration, condenser, HVAC or replacement project?

Send us the complete model number, required quantity and application requirements. For replacement applications, you can also provide the existing fan nameplate and installation information to help confirm the required model before ordering.

 

 

 

Related Products

Message